Share:


Thermal Gas Mass Flow Meter STG Series



STG Series 

Thermal Gas Mass Flow Meter

The thermal mass flow meter is designed on the basis of thermal disperion, and adopts method of constant differential temperature to measuring gas flow. It has advantages of small size, easy installation, high reliablity and high accuracy.
 
Rank Subsystem/Facility/Load Share of Fab Electricity Key Driver / Function
1 Chiiler & HVAC/Cleanroom Air Handling  40%-50% Recirculation fan(FFUs),Chillers, and make-up units (MAU),maintaining class 1-100 cleanroom temmperature, humidity and air flow
2 Compressor Systems (CDA generation) 15%-20% continuos 24/7 high pressure supply to drive pneumatic robotic, lens/vacuum purges,and dry etching tools
3 process Vacuum system & Scrubbers 10%-15% Point-of-use vacuum pumps for process chambers (CVD, ALD, Etch) and exhaust abatement systems.
4 UPW (Ultra-Pure Water) & Wastewater 5%-10% High-pressure pumps, UV polishers, and reverse osmosis (RO) filtration banks.
5 Cleanroom Lighting & Auxiliaries 3%-5% Cleanroom lighting, office power, and secondary utility circulation.
 

Key Energy Optimization Strategies for Fab Compressor Systems

Continuous Monitoring (Thermal Mass Flow & Power Loggers): Tracking specific power consumption (kW/ 100 CFM or kWh / Nm3 ) continuously. A baseline rise in specific power instantly flags air leaks or dryer purge inefficiencies before power bills surge.

CFM to kW Formula and Example

The formula for calculating the CFM to kW ratio is:

CFM to kW Ratio = CFM ÷ kW

For example, if your air compressor has a CFM rating of 10 and a kW rating of 1.5, the calculation would be:

10 ÷ 1.5 = 6.67

This means the CFM to kW ratio of the compressor is 6.67.

If you prefer using an automated tool, you can utilize an air compressor kW to CFM calculator to simplify the process.

This kW to CFM converter can be applied to different air compressor models to determine their efficiency and help you select the right compressor size for your needs.

 

Worked Example Calculation

Scenario: A 100 HP rotary screw compressor room running a production shift records the following average operational readings:

  • Measured 3-Phase Voltage (V): 415 V

  • Measured Line Current (I): 135A

  • Measured Power Factor (cos ): 0.88

  • Measured Flow Rate (from Thermal Mass Meter): 420 CFM

     

    1. Calculate Real Electrical Power Draw:

2. Calculate Specific Power Consumption:
 
Specific Power (kW/100 CFM) Efficiency Level Typical System Status / Action
< 18.0 Excellent Multi-stage centrifugal or high-efficiency VSD running near full load.
18.0 - 22.0 Good / Standard Well-maintained rotary screw operating in its sweet spot.
22.1 - 28.0 Fair / Poor Excessive unloading, choked intake filters, or moderate air leaks.
> 28.0 Critical Waste Heavy modulation/unloading losses, large plant leaks, or severe dryer purge air waste.


 Inquiry - Thermal Gas Mass Flow Meter STG Series